    Default The problem with the cooling


    The problem of such a mother ADR at 785g chipset on it 3 outputs for the FAN, cpu_fan and so on. they are all busy but there is a need to install two fans of hull (4 pin outputs) as it can be done? What wiring to buy?

  2. #2
    Honorato Idurre's Avatar
    Honorato Idurre is offline Junior Member
    Join Date
    Sep 2009
    Posts
    80
    Ranking
    3

    Default

    The old 3-wire connection has 3 wires - power, land, and the sensor speed. A contemporary has 4 wires - added wire PWM , which is managing the amount of energy distributed by the scheme fan in the fan (in plain language - governed speed fan). However, for compatibility fan control circuit is made in such a way that in the absence of signal PWM (ie, control signal), it works just the same, standard mode. 's All. You want to use a PWM fan on a standard 3-pin connector - please.

  3. #3
    andy nadal's Avatar
    andy nadal is offline Junior Member
    Join Date
    Sep 2009
    Posts
    37
    Ranking
    0

    Default

    And it is possible to explain it more accessible? that for the standard mode? can I reduce the speed of fans when connected to 3x pin?

    I do not understand if I cpu_fan to connect the hub and the wire cooler percent plunge in the hub, and stick more to the hub 4 fans that nothing bad will happen? Connector on the motherboard does not melt? And in the BIOS or anywhere else you can reduce the speed of all fans? each separately? ps I do not have computer education, I apologize if the questions seem silly.

  4. #4
    Florita Garbin's Avatar
    Florita Garbin is offline Junior Member
    Join Date
    Sep 2009
    Posts
    79
    Ranking
    3

    Default

    Well you might say ... now seen in the description - speed, flow, noise ... it is now, and pointed to the standard, that is "full" mode. Reduce the speed ... But if on the socket where you plug (3 pin) is adjustable - it is regulated. The mat. boards such adjustment usually is. Included in the Hardware Monitor. Triggered after a reboot. Just not governed but simply supply voltage.

    A hub is not in vain has a separate connection to PSU. It was from there will take up electricity, and the connector on the mother does not suffer. Yes, the BIOS must include the management of ventilators.

  5. #5
    Esequiel Fanuc's Avatar
    Esequiel Fanuc is offline Junior Member
    Join Date
    Sep 2009
    Posts
    80
    Ranking
    3

    Default

    to connect the PWM fans again have to apply the tools and spoil connectors. And since that fit of course.

Thread Information

Users Browsing this Thread

There are currently 1 users browsing this thread. (0 members and 1 guests)

Posting Permissions

  • You may not post new threads
  • You may not post replies
  • You may not post attachments
  • You may not edit your posts
  •  
SEO by SubmitEdge
SEO by SubmitEdge

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89